BZCGG - 6085-05 PTFE COATED FIBERGLASS FABRIC W/SILICONE ADHESIVE

  • MSDS: BZCGG
  • Manufacturer: TACONIC PLASTICS LTD
  • Product Name: 6085-05 PTFE COATED FIBERGLASS FABRIC W/SILICONE ADHESIVE
  • National Stock Number: 8040-00F047074
Product Identification

Product ID:6085-05 PTFE COATED FIBERGLASS FABRIC W/SILICONE ADHESIVE
MSDS Date:05/23/1994
FSC:8040
NIIN:00F047074
MSDS Number: BZCGG

Responsible Party
TACONIC PLASTICS LTD
COONBROOK RD
PETERSBURG, NY 12138-5000
US

Emergency Phone: 1-800/833-1805

Info Phone: 518-658-3202

Cage: 59688

Contractor
TACONIC PLASTICS LTD
PETERSBURG, NY 12138-9715 US

Cage: 59688

Ingredients

ETHYLENE, TETRAFLUORO- POLYMER (POLYTETRAFLUOROETHYLENE),

CAS: 116-14-3

RTECS: KX4025000

Fraction By Weight: <39.4%


GLASS OXIDE, FIBER GLASS WOOL, LEAD BOROSILICATE GLASS

CAS: 65997-17-3

Fraction By Weight: 31.8-33%


POLYSILOXANE

Fraction By Weight: 27-30.3%

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: POLYMER FUME FEVER.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SHORTNESS OF BREATH, FLU-LIKE SYMPTOMS.

First Aid

First Aid:OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:WATER, CO2, FOAM/CHEMICAL AS APPROPRIATE TO
IGNITION SOURCES.
Fire Fighting Procedures:PROTECT FROM HYDROGEN FLUORIDE & WEAR SCBA.
Unusual Fire/Explosion Hazard:WILL BURN ONLY W/AN IGNITION SOURCE.
TOXIC FUMES EMITTED AT HIGH TEMPS (800F).

Accidental Release

Spill Release Procedures:NORMAL CLEANUP

Handling

Handling and Storage Precautions:DON'T EXPOSE TO TEMP >500F. STORAGE
TEMP: 65-75F.
Other Precautions:DON'T SMOKE WHILE HANDLING THIS MATERIAL, AVOID
GETTING DUST/PARTICLES ON TABACCO.

Exposure Controls

Ventilation:ADEQUATE VENTILATION
Supplemental Safety and Health

Chemical Properties

Spec Gravity:1.9
Solubility in Water:INSOLUBLE
Appearance and Odor:SOLID TAN TO BROWN PLIABLE SHEET

Stability

Stability Indicator/Materials to Avoid:YES
MOLTEN ALKALI METALS
Stability Condition to Avoid:HIGH TEMPERATURES, IGNITION SOURCES
Hazardous Decomposition Products:CARBONYL FLUORIDE, HYDROGEN FLUORIDE

Disposal

Waste Disposal Methods:LANDFILL IAW/FEDERAL, STATE & LOCAL REGULATIONS.
MATERIAL IS INERT & ISN'T A RCRA LISTED.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.